Reliability test Report
Division | Equipment | Process | Initial Value | Result | Standard | QC Result |
---|---|---|---|---|---|---|
Salt Spray Test | 1.NaCl 5% 2.Tem'=35°c 3.Spray 72hr |
Plating Good | White-Rust | White-Rust=OK Red-Rust=NG |
OK | |
Life Cycle Test | 1. 10sec/cycle "2.100,000 Cycle Continuous Test" |
Movement Good | Movement Good | Movement Good=OK Damage/Broken=NG |
OK | |
Torque Rate of Change | 1.NaCl 5% 2.35°c 3.Spray 72hr |
4.5N | 4.1N | ±10% Below=OK ±10% Excess=NG |
OK | |
Torsion Spring Rate of Change | 1. 10sec/cycle "2.100,000 Cycle Continuous Test" |
Base Line=0° | Baseline Angle of Change=3° |
±5° Below=OK ±5° Excess=NG |
OK |
Division | Salt Spray Test |
---|---|
Equipment | |
Process | 1.NaCl 5% 2.Tem'=35°c 3.Spray 72hr |
Initial Value | Plating Good |
Result | White-Rust |
Standard | White-Rust=OK Red-Rust=NG |
QC Result | OK |
Division | Life Cycle Test |
---|---|
Equipment | |
Process | 1. 10sec/cycle "2.100,000 Cycle Continuous Test" |
Initial Value | Movement Good |
Result | Movement Good |
Standard | Movement Good=OK Damage/Broken=NG |
QC Result | OK |
Division | Torque Rate of Change |
---|---|
Equipment | |
Process | 1.NaCl 5% 2.35°c 3.Spray 72hr |
Initial Value | 4.5N |
Result | 4.1N |
Standard | ±10% Below=OK ±10% Excess=NG |
QC Result | OK |
Division | Torsion Spring Rate of Change |
---|---|
Equipment | |
Process | 1. 10sec/cycle "2.100,000 Cycle Continuous Test" |
Initial Value | Base Line=0° |
Result | Baseline Angle of Change=3° |
Standard | ±5° Below=OK ±5° Excess=NG |
QC Result | OK |